Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

The Spray-Applied Fireproofing Special Inspector Exam, Illustrated The Whole Inspection in 9 Steps, Always in the Same Order

The approved fire-resistance design, surface prep, wet and dry mix, thickness readings, density, bond strength, coatings, repairs and reports. Every topic gets its own page: the drawing first, then what you need to know. 69 illustrated pages.

START STUDYING THIS WAY

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageEach reading point and each test drawn, with the explanation right beside it
69 illustrated pages9 parts, from the job and the exam to the open-book review
Up-to-date sourcesIBC Chapter 17, ASTM E605 and ASTM E736
PDF by emailFormat

Look Inside the Book

Every page has a big drawing and a box with the numbers and steps you need to know:

The fireproofing inspection route, with the 5 checks the IBC asks for SFRM
The fireproofing inspection route, with the 5 checks the IBC asks for SFRM
Section 1705.15: inspection is based on the fire-resistance design in the approved documents.
Section 1705.15: inspection is based on the fire-resistance design in the approved documents.
IBC Section 1705.15.2: inspect the prepared surface before SFRM is applied
IBC Section 1705.15.2: inspect the prepared surface before SFRM is applied
Wet mix vs. dry mix: where the water goes in, and what the inspector watches in each
Wet mix vs. dry mix: where the water goes in, and what the inspector watches in each
IBC: thickness on at least 25% of structural members per floor.
IBC: thickness on at least 25% of structural members per floor.
In-place density can't be less than the approved design density, in pcf per ASTM E605.
In-place density can't be less than the approved design density, in pcf per ASTM E605.
Cohesion breaks inside the SFRM; adhesion breaks at the steel. Log which one.
Cohesion breaks inside the SFRM; adhesion breaks at the steel. Log which one.
Coatings: IBC Section 1705.16 and AWCI 12-B, not the SFRM density and pull tests.
Coatings: IBC Section 1705.16 and AWCI 12-B, not the SFRM density and pull tests.

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 9 parts and 65 topics.

The Problem Isn't You. It's How It Was Explained.

You're standing under a beam that's about to get sprayed. The crew has the hose ready, and you're the one who has to say the steel is ready.

Your references cover it in long paragraphs: what can't be on the steel, what's allowed to stay on it, what has to go on before the fireproofing. You read it at the desk, but at the beam you can't picture it.

IBC Section 1705.15.2: inspect the prepared surface before SFRM is applied

In this book, surface condition is one page. A drawn steel member shows what "ready" looks like, and a box next to it lists what you check before the hose starts.

The approved fire-resistance design, wet vs. dry mix, the thickness gauge, density and cohesion vs. adhesion work the same way: each one gets its own page.

So you look at the steel, you know what to check, and you make the call without going back to the manual.

COMPARE FOR YOURSELF

Same Topic, Two Ways to Study It

THIS
  • The manual: line after line
  • Design listings explained only in words
  • You show up on site still unsure
The special inspector shall verify that sprayed fire-resistive materials are applied in conformance with the approved fire-resistance design as referenced in the approved construction documents. Said design, generally identified by its listing designation, establishes the assembly configuration, the required hourly rating, the restrained or unrestrained classification, the minimum member size or W/D ratio, and the required thickness and density of the material, and any deviation therefrom shall require documented approval by the registered design professional prior to application of the material.
FOR THIS
  • The fire-resistance design in one drawing
  • The key numbers in a box
  • You see it and you get it
Section 1705.15: inspection is based on the fire-resistance design in the approved documents.
CONTENTS

Take a Look at the 9 Parts and 65 Topics

The job and the exam, documents, steel prep and conditions, application, thickness readings, density, bond strength, coatings, repairs and reports, and the open-book review: 69 pages, all illustrated.

IThe Job and the Exam · pp. 5-11
  1. What a Fireproofing Special Inspector Actually Checks
  2. Why Fireproofing Exists: Steel Loses Strength with Heat
  3. SFRM vs. Mastic and Intumescent Coatings
  4. Continuous vs. Periodic Inspection
  5. Who You Report To
  6. The Certification Exam at a Glance
  7. How This Book Is Organized
IIBefore the Hose Starts: Documents · pp. 12-18
  1. The Approved Fire-Resistance Design
  2. Reading a Design Listing in 5 Boxes
  3. Restrained vs. Unrestrained Ratings
  4. W/D Ratio: The Number That Changes Thickness
  5. Beam Substitution Equation, Worked Out
  6. Submittals You Need on Site
  7. The Preconstruction Meeting
IIISteel Prep and Conditions · pp. 19-25
  1. Surface Condition: What 'Ready' Looks Like
  2. Painted or Primed Steel
  3. Bonding Agents and Metal Lath
  4. Hangers, Clips and Attachments First
  5. Temperature Before, During and After
  6. Ventilation and Drying
  7. Pre-Spray Checklist
IVApplication · pp. 26-31
  1. Wet vs. Dry Mix Systems
  2. Passes and Build-Up
  3. Checking Wet Thickness While Spraying
  4. Tamping, Rolling and Surface Finish
  5. Sealers and Top Coats
  6. Visual Defects to Flag
VThickness Readings · pp. 32-41
  1. The Thickness Gauge and How to Read It
  2. How Many Readings on Floors, Roofs and Walls
  3. Fluted and Flat Deck: Where to Probe
  4. How Many Members to Test
  5. Wide-Flange Beams: 9 Readings at Each End
  6. Joists and Trusses: 7 Readings
  7. Wide-Flange Columns: 12 Readings
  8. HSS and Pipe Columns: At Least 4 Readings
  9. The 1/4-Inch Rules for Individual Readings
  10. Average Thickness, Worked Example
VIDensity · pp. 42-47
  1. Why Density Matters
  2. How Often to Sample Density
  3. Cutting the Sample
  4. Drying the Sample to Constant Weight
  5. Density in pcf, Worked Example
  6. Low Density: What to Check Next
VIIBond Strength · pp. 48-53
  1. Cohesion vs. Adhesion
  2. Minimum Bond Strength by Building Height
  3. How Often to Test Bond Strength
  4. Running the Pull Test Step by Step
  5. Bond Strength in psf, Worked Example
  6. Bond Test on Primed or Painted Steel
VIIICoatings, Repairs and Reports · pp. 54-61
  1. Mastic and Intumescent Coatings: What Changes
  2. Damage After Other Trades
  3. Patching: Same Material, Same Thickness
  4. Thin Spots: Respray and Re-Measure
  5. The Daily Log
  6. Writing a Nonconformance
  7. Test Report Sheets for Thickness, Density and Bond
  8. The Final Report
IXOpen-Book Exam and Review · pp. 62-69
  1. How to Tab Your References
  2. Where to Find Each Answer
  3. Time Per Question: A Pacing Plan
  4. The Numbers Page
  5. Mix-Ups to Avoid: Beams, Joists, Columns
  6. Common Field Mistakes
  7. Full Inspection Checklist
  8. Glossary at a Glance

One Page, One Topic, All Clear

Think of it this way:

You're on the deck with a W-beam overhead and the gauge in your hand. You need to know how many readings to take, and where.

You open the page on wide-flange beams and see the beam drawn in section, with every reading point marked on the flanges and the web.

IBC: thickness on at least 25% of structural members per floor.

Same with columns, joists, fluted deck, density samples and the pull test: each one on its own page.

Fireproofing Inspector Illustrated is 9 parts and 65 topics, all drawn, and it ends with the review: the numbers page, a pacing plan for the open-book exam and a full inspection checklist.

What you see drawn, you don't have to memorize.

What's Inside Fireproofing Inspector Illustrated:

Ipp. 5-11

The Job and the Exam

What a fireproofing special inspector actually checks, why steel needs protection from heat, SFRM vs. coatings, continuous vs. periodic inspection, who you report to and the exam at a glance.

IIpp. 12-18

Before the Hose Starts: Documents

The approved fire-resistance design, reading a design listing in 5 boxes, restrained vs. unrestrained, the W/D ratio, the beam substitution equation worked out, submittals and the preconstruction meeting.

IIIpp. 19-25

Steel Prep and Conditions

What ready steel looks like, painted or primed steel, bonding agents and lath, hangers and clips first, temperature, ventilation and the pre-spray checklist.

IVpp. 26-31

Application

Wet vs. dry mix, passes and build-up, wet thickness checks while spraying, tamping and finish, sealers and the visual defects to flag.

Vpp. 32-41

Thickness Readings

The thickness gauge, readings on floors, roofs and walls, fluted and flat deck, how many members to test, beams, joists, columns, HSS, the 1/4-inch rules and the average worked out.

VIpp. 42-47

Density

Why density matters, how often to sample, cutting and drying the sample, density in pcf worked out and what to check when it comes in low.

VIIpp. 48-53

Bond Strength

Cohesion vs. adhesion, minimum bond strength by building height, test frequency, the pull test step by step, bond strength in psf worked out and testing on primed steel.

VIIIpp. 54-61

Coatings, Repairs and Reports

What changes with mastic and intumescent coatings, damage from other trades, patching, thin spots, the daily log, nonconformance reports, test sheets and the final report.

IXpp. 62-69

Open-Book Exam and Review

How to tab your references, where each answer lives, a pacing plan, the numbers page, beam-joist-column mix-ups, common field mistakes, the full checklist and a glossary.

At the end of the book: A tabbing guide for the open-book exam, a numbers page, a full inspection checklist and a glossary.

Plus: 2 Free Books

Fireproofing Exam-Style Practice Questions

BONUS 1: «Fireproofing Exam-Style Practice Questions»

Value on its own: US$ 17.90

Practice with questions written like the real exam, each one with the answer and the page where you find it, so you learn to look things up fast before test day.

Field Quick-Reference Cards

BONUS 2: «Field Quick-Reference Cards»

Value on its own: US$ 14.90

One-page cards for thickness readings, density samples and bond checks that you can print and keep in your truck or clipboard on site.

Fireproofing Inspector Illustrated with 2 Free Books

  • Fireproofing Inspector Illustrated: 69 illustrated pagesUS$ 63
  • BONUS 1: Fireproofing Exam-Style Practice QuestionsUS$ 17.90
  • BONUS 2: Field Quick-Reference CardsUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 95.80
YOUR PRICE:
US$ 27
You save US$ 68.80
YES, I WANT FIREPROOFING INSPECTOR ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Fireproofing Inspector Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're studying for the certification

You're studying for the certification

The whole inspection in the order you do it on site, one drawing per topic, so the code and the standards finally line up.

Your exam date is set

Your exam date is set

A tabbing guide, a pacing plan and a numbers page, so in an open-book exam you know where each answer lives.

You already inspect on site

You already inspect on site

Reading points on every shape, density and pull-test steps, and how to write it up, ready to print and keep in the truck.

Everything You Get Today

US$ 95.80US$ 27
YES, I WANT FIREPROOFING INSPECTOR ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Fireproofing Inspector Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I already inspect steel or concrete and need to add spray-applied fireproofing?

Yes. It doesn't explain what a beam is: it goes straight to the fireproofing inspection, in the order you do it on site, from the design listing to the final report.

Where does the content come from?

From the IBC Chapter 17 special inspection requirements, ASTM E605 (thickness and density), ASTM E736 (bond strength) and the AWCI technical manuals. Section numbers can shift between IBC editions, so each page names the requirement by what it checks: you can find it in the edition your exam or jurisdiction uses. Everything is explained with our own drawings, not copied from the standards.

Is it official material?

No. It's an independent illustrated study guide. It doesn't give you a certificate, a credential or exam credit: the certification only comes from passing the exam. It is not affiliated with or endorsed by ICC, ASTM, AWCI, UL or any exam body.

It's open book. Why do I need this if I already have the code and the standards?

Because open book only helps if you know where to look. This book doesn't replace your references: you still bring the code and the standards. It shows each topic as a drawing and tells you where its answer lives, with a tabbing guide and a pacing plan. It isn't a course and doesn't replace formal training or field experience.

Are the practice questions the ones on the exam?

No. They're written for this book in the style of the exam, each with the answer and where to find it. They are not official exam questions.

When and how do I get it?

PDF by email, sent to the address you enter at checkout. The 2 bonus books come with it.

Do I have to pay every month?

No. It's a one-time payment. No subscription.

Can I have it on paper?

Yes. It's a printable PDF: print the whole book or just the pages you want on site.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading the standards with nothing sticking.

Reading points on a beam: you see them drawn, and that's it.

You walk into the exam and onto the site knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 27 · Guarantee: 30 days · PDF by email

YES, I WANT FIREPROOFING INSPECTOR ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.